Sea gull lighting 31523-845 Installation Guide Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
INSTALLATION HC-1145
FINAL ASSEMBLY
STEP 1:
S
TEP 5:
I
MPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET
BOX.
Secure mounting bar (A) to outlet box with outlet box screws (not
s
upplied). Thread nut (B) on nipple (C) so that 3 threads are exposed
above nut (B). Thread nipple (C) into mounting bar (A) and secure
with nut (B). Thread screw collar (E) to nipple (C).
STEP 2:
Using 2 pairs of pliers, open one link of chain (S) and connect it to
the fixture loop (J) at the top of the fixture.
A. Take note of the color of the wire(s) on your fixture. Identify which
group your fixture wire(s) falls into and connect the wires according
to the directions below:
STEP 3:
STEP 4:
Slide the screw collar ring (G) and canopY (H), in that order, over
chain (S). Open one link on the other end of the chain (S) and
attach it to the screw collar (E) which has been mounted to the
ceiling nipple (C).
BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY.
*Note: When parallel wire is used, the tracer wire is square shaped
or ridged and less tracer wire is round in shape or smooth.
(Seen best when viewed from wire end.)
T
o separate wires, grasp
the ends of each wire and pull apart.
B. Take your fixture wire(s) from group A and place evenly against
the black wire from the outlet box.
DO NOT twist wires together
before using wire connectors.
C. Fit a wire connector (not supplied) over the wires and thread the
connector clockwise until you feel a firm resistance.
D. Gently try to remove the wires from the connector.If you can pull
the wires out, carefully re-do steps B and C, as above and check
again for a firm connection.
E. Connect the fixture wire from group B to the white wire from the
outlet box in the same manner.
GROUNDING INSTRUCTIONS: The green grounding screw (D) is
to be inserted into the hole with two raised dimples provided on the
m
ounting bar (A). Wrap the ground wire (F) from the fixture (if supplied)
and the ground wire from the outlet box (bare metal or green
insulated wire) around the green grounding screw (D) on the
m
ounting bar (A) if uninsulated wire is on the mounting bar (A),
connect the ground wire (F) from the fixture (if supplied) and the
outlet box to it using a small wire connector (not supplied).
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
GROUP A: CONNECT TO BLACK
HOUSE WIRE
BLACK
WHITE
*
PARALLEL WIRE (ROUND & SMOOTH)
*P
ARALLEL WIRE (SQUARE & RIDGED)
GROUP B: CONNECT TO WHITE
HOUSE WIRE
Place glass (R) in socket cup (I).
CLEANING
ORDERING PARTS
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap.
Do not use abrasive materials such as scouring pads or powders,
steel wool or abrasive paper.
Keep this sheet for future reference, and in case you need to order
replacement parts. Parts for this fixture can be ordered from place of
purchase. Be sure to use exact wording from illustration when
ordering parts.
STEP 1:
STEP 2:
After wires are connected, tuck them carefully inside outlet box.
Raise canopy (H) against ceiling and thread the screw collar ring (G)
to the screw collar (E).
Make sure no bare wires can be seen outside wire connectors.
Install lamps (not supplied).
STEP 3:
Page view 1
1 2

Comments to this Manuals

No comments